Package:
Energy-ADE
|
Definition:
A thermal zone is a zone of a building which serves as unit for the building heating
and cooling simulation. For the simulation, a thermal zone is considered as isothermal.
It is a semantic object, which may be or not related to a geometric entity.
|
Subtype of:
_CityObject
|
Type:
Feature type
|
|
Overview of characteristics:
|
back to top
Name:
|
additionalThermalBridgeUValue
|
Definition:
|
Transmission heat loss contribution [W/m².K] of the thermal bridges of the thermal
zone shell to the overall UValue.
|
Voidable:
|
false
|
Multiplicity:
|
0..1
|
Value type:
|
Measure
|
|
back to top
|
back to top
Name:
|
cooledFloorArea
|
Definition:
|
Actively cooled floor area [m²]
|
Voidable:
|
false
|
Multiplicity:
|
0..1
|
Value type:
|
Area
|
|
back to top
Name:
|
effectiveThermalCapacity
|
Definition:
|
Thermal capacity [Wh/K] of the zone including the contributing construction layers
and zone fournitures.
|
Voidable:
|
false
|
Multiplicity:
|
0..1
|
Value type:
|
Measure
|
|
back to top
Name:
|
heatedFloorArea
|
Definition:
|
Actively heated floor area [m²]
|
Voidable:
|
false
|
Multiplicity:
|
0..1
|
Value type:
|
Area
|
|
back to top
Name:
|
indirectlyHeatedAreaRatio
|
Definition:
|
[find precise definition]
|
Voidable:
|
false
|
Multiplicity:
|
0..1
|
Value type:
|
Scale
|
|
back to top
Name:
|
infiltrationRate
|
Definition:
|
Air change rate [1/h] due to air leakage of the zone shell.
|
Voidable:
|
false
|
Multiplicity:
|
0..1
|
Value type:
|
Measure
|
|
back to top
Name:
|
relates
|
Voidable:
|
false
|
Multiplicity:
|
0..*
|
Value type:
|
UsageZone (feature type)
|
|